• head_banner_01

Polycrystalline Module

Short Description:


Product Detail

FAQ

Product Tags

ADVANCED PERFORMANCE & PROVEN ADVANTAGES
High module conversion efficiency up to 18.30% through innovative five busbar cell
technology.
Low degradation and excellent performance under high temperature and low light conditions.
Robust aluminum frame ensures the modules to withstand wind loads up to 3600Pa and snow loads up to 5400Pa.
High reliability against extreme environmental conditions (passing salt mist, ammonia and hail tests).
Potential induced degradation (PID) resistance.

CERTIFICATIONS
IEC 61215, IEC 61730, UL 1703, IEC 62716, IEC 61701, IEC TS 62804, CE, CQC, ETL(USA), JET(Japan), J-PEC(Japan),KS(South Korea),BIS(India),MCS(UK),CEC(Australia), CSI Eligible(CA-USA), Israel Electric(Israel), InMetro(Brazil), TSE(Turkey)
ISO 9001:2015: Quality management system
ISO 14001:2015: Environmental management system
ISO 45001:2018: Occupational health and safety management system

SPECIAL WARRANTY
20 years product warranty
30 years linear power output warranty

ELECTRICAL CHARACTERISTICSAT STC
Maximum Power(Pmax) 325W 330W 335W 340W 345W 350W 355W
Open Circuit Voltage(Voc) 45.7V 45.9V 46.1V 46.3V 46.5V 46.7V 46.9V
Short Circuit Current(Isc) 9.28A 9.36A 9.44A 9.52A 9.60A 9.68A 9.76A
Voltage at Maximum Power(Vmp) 37.1V 37.3V 37.5V 37.7V 37.9V 38.1V 38.3V
Current at Maximum Power(Imp) 8.77A 8.85A 8.94A 9.02A 9.11A 9.19A 9.27A
Module Efficiency(%) 16.75 17.01 17.26 17.52 17.78 18.04 18.3
Operating Temperature -40℃ to+85℃
Maximum System Voltage 1000V DC/1500V DC
Fire Resistance Rating Type 1(in accordance with UL 1703 )/Class C(IEC 61730)
Maximum Series Fuse Rating 15A

STC: lrradiance 1000W/m² , Cell temperature 25℃,AM1.5;Tolerance of Pmax:±3%; Measurement Tolerance:±3%

ELECTRICAL CHARACTERISTICSAT NOCT
Maximum Power (Pmax) 241W 244W 248W 252W 256W 259W 263W
Open Circuit Voltage (Voc) 42.0V 42.2V 42.4V 42.6V 42.8V 43.0V 43.2V
Short Circuit Current (lsc) 7.52A 7.58A 7.65A 7.71A 7.78A 7.84A 9.91A
Voltage at Maximum Power (Vmp) 33.7V 33.9V 34.1V 34.3V 34.5V 34.7V 34.9V
Current at Maximum Power (lmp) 7.16A 7.20A 7.28A 7.35A 7.42A 7.47A 7.54A

NOCT: Irradiance 800W/m² , Ambient temperature 20℃, Wind Speed 1 m/s

MECHANICAL CHARACTERISTICS
Cell type Polycrystalline 6inch
Number of cells 72(6x12)
Module dimensions 1956x992x35mm (77.01x39.06x1.38inches)
Weight 21kg (46.3lbs)
Front cover 3.2mm (0.13inches) tempered glass with AR coating
Frame Anodized aluminum alloy
Junction box IP67, 3 diodes
Cable 4mm²(0.006inches²),1000mm (39.37inches)
Connector MC4 or MC4 compatible
TEMPERATURE CHARACTERISTICS
Nominal Operating Cell Temperature (NOCT) 45℃±2℃
Temperature Coefficients of Pmax -0.39%/℃
Temperature Coefficients of Voc -0.30%/℃
Temperature Coefficients of lsc 0.05%/℃
PACKAGING
Standard packaging 31pcs/pallet
Module quantity per 20' container 310pcs
Module quantity per 40' container 744pcs(GP)/816pcs(HQ)

  • Previous:
  • Next:

  • Write your message here and send it to us

    Related products

    • ATS

      ATS

      AUTOMATIC TRANSFER SWITCH -ATS For home and other circumstances, Automatic Transfer Switch (ATS) is essential. ATS can automatically transfer load between the main power and the emergency (generator set) without operator. When the main power fails or voltage drops below 80% of normal voltage, the ATS will start the emergency generator set after a preset time of 0-10 seconds (adjustable) and transfer the load to the emergency power (generator set). On the contrary, when the main power recovers...

    • KT-SDEC Series Diesel Generator

      KT-SDEC Series Diesel Generator

      Description: Shanghai Diesel Engine Co., Ltd. (SDEC), with SAIC Motor Corporation Limited as its main shareholder, is a large state-owned high-tech enterprise engaged in research and development and manufacture of engines, engine parts and generator sets, possessing a state-level technical center, a postdoctoral working station, world-level automatic production lines and a quality assurance system that meets passage cars standards. Its former was Shanghai Diesel Engine Factory that was establ...

    • KT Yuchai Series Diesel Generator

      KT Yuchai Series Diesel Generator

      Description: Founded in 1951, Guangxi Yuchai Machinery Group Co., Ltd. (Yuchai Group for short) is headquartered in Yulin, Guangxi Zhuang Autonomous Region. It is a company in investment and financing management, centered on capital operation and asset management. As a large-scale state-owned business conglomerate, it has more than 30 wholly-owned, holding, or joint-stock subsidiaries, with total assets of 40.5 billion yuan and nearly 20,000 employees. Yuchai Group is an internal combustion e...

    • KT Natural Gas Generator set

      KT Natural Gas Generator set

      Requirements for Natural gas: (1) The methane content should not be lower than 95%. (2) The natural gas temperature should be between 0-60。 (3) No impurity should be in the gas. Water in the gas should be less than 20g/Nm3. (4) Heat value should be at least 8500kcal/m3, if less than this value, the power of the engine will be declined. (5) Gas pressure should be 3-100KPa, if the pressure is less than 3KPa, booster fan is necessary. (6) The gas should be dehydrated and desulfurized. Make sure...

    • KT-Yangdong Series Diesel Generator

      KT-Yangdong Series Diesel Generator

      Description: Yangdong Co.,Ltd  is a subsidiary of  YTO Group. Yangdong Co.,Ltd  with  "integrity, pragmatic, innovative" concept to provide  high-tech, high-performance,  high-quality products and first  class service for the purpose,  adhere to scientific and technological innovation, to  become experts in power  integrated solution. The company increased R & D efforts, relying on YTO Group National Technical Center's technical superiority and cooperate with the Southwest Research Instit...

    • Use Bridge to Lay Along The Ground

      Use Bridge to Lay Along The Ground

      Description: The charging pile is installed in a column type. After the bridge is vertically led down to the ground on the attached wall or column, it is laid along the ground to the bottom of the charging pile, and the charging pile enters the line.

    WhatsApp Online Chat !